Lincoln Aviator: Climate Control / Automatic Climate Control

Note: Depending on your vehicle option
package, the controls may look different
from what you see here.
Note: You can switch temperature units
between Fahrenheit and Celsius.
Note: You can control some of the climate
features through the touchscreen.
Note: For Hybrid vehicles, the air
conditioning compressor may run and airflow
may be felt when the climate control is off
to provide cooling to the battery.
Accessing the Air Distribution Controls
Press and release the button to
activate the selection screen.
From the screen you can direct air to the
windshield, instrument panel or footwell
vents. You can direct air through any
combination of these vents.
Accessing the Climate Control Menu
Press and release the button to
access additional controls for the
front climate system.
Accessing Rear Climate Controls
Press and release the button to
access additional controls for the
rear climate system.
Setting the Blower Motor Speed

Turn the control to adjust the volume of air
circulated in the vehicle.
Setting the Temperature
Press the toggle button on the
left-hand side
of the climate control upward or downward
to set the left-hand temperature.
Note: This control also adjusts the right-hand
side temperature when you switch off dual
zone mode.
Press the toggle button on the right-hand
side of the climate control upward or
downward to set the right-hand temperature.
Switching Auto Mode On and Off
Press and release the button to
switch on automatic operation.
Repeatedly press the button to
adjust auto mode.
The system adjusts the blower motor speed,
air distribution, air conditioning operation,
and outside or recirculated air to reach and
maintain the temperature you have set.
Under high humidity conditions, the system
adjusts the blower motor speed, air
distribution and air conditioning operation
to reduce window fogging.
Note: The system starts at the previous
setting when you switch on AUTO mode.
Note: You can also switch off dual zone
mode by pressing and holding the button for
more than two seconds.
Auto Mode Indicator Status

Switching the Air Conditioning On and
Off
Press and release the button.
Use air conditioning with recirculated air to
improve cooling performance and efficiency.
Note: In certain conditions, such as
maximum defrost, the air conditioning
compressor may continue to operate even
though you switch off the air conditioning.
Note: The A/C LED light may turn on and off
based on the temperature setting or the
current conditions.
Switching the Climate Control On and Off
Press and release the button.
Note: Your vehicle may not have a physical
button. You can use the touchscreen to turn
the climate control on and off.
Switching Maximum Air Conditioning On and Off
Press and release the button for
maximum cooling.
The driver and passenger temperatures are
set to LO, recirculated air flows through the
instrument panel air vents, air conditioning
turns on and the blower motor adjusts to the
highest speed.
Switching Maximum Defrost On and Off
Press and release the button for
maximum defrosting.
The driver and passenger temperatures are
set to HI, air flows through the windshield air
vents, and the blower motor adjusts to the
highest speed.
Note: Depending on your region, air
conditioning turns on.
You can also use this setting to defog and
clear the windshield of a thin covering of ice.
Note: To prevent window fogging, you
cannot select recirculated air when
maximum defrost is on.
Note: The heated rear window also turns on
when you select maximum defrost.
Switching Recirculated Air On and Off
Press and release the button to
switch between outside air and
recirculated air.
The air currently in the passenger
compartment recirculates. This may reduce
the time needed to cool the interior, when
used with A/C, and reduce unwanted odors
from entering your vehicle.
Note: Recirculated air may turn off, or
prevent you from switching on, in all air flow
modes except MAX A/C to reduce the risk
of fogging. Recirculation may also turn on
and off in various air distribution control
combinations during hot weather to improve
cooling efficiency.
General Hints
Note: Prolonged use of recirculated air may
cause the windows to fog up.
Note: You may feel a small amount of air
from the footwell air vents regardless of the
air distribution setting...
Other information:
Diagnostic Trouble Code (DTC) Chart
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods (100-00 General Information, Description and Operation).
Diagnostic Trouble Code Chart
Module
DTC
Description
Action
ACCM
B11EE:19
A/C Compressor: Circuit Current Above Threshold
GO to Pinpoint Test AJ
ACCM
B11EE:41
A/C Compressor: General Checksum Failure
GO to Pinpoint Test AS
ACCM
B11EE:4B
A/C Compressor: Over Temperature
GO to Pinpoint Test AJ
ACCM
B11EE:92
A/C Compressor: Performance or Incorrect Operation
GO to Pinpoint Test AJ
ACCM
P0562:00
System Voltage Low: No Sub Type Information
GO to Pinpoint Test AJ
ACCM
P0563:00
System Voltage High: No Sub Type Information
GO to Pinpoint Test AJ
ACCM
P0AFA:16
Hybrid/EV Battery System Voltage Low: Circuit Voltage Below Threshold
GO to Pinpoint Test AJ
ACCM
P0AFB:17
Hybrid/EV Battery System Voltage High: Circuit Voltage Above Threshold
GO to Pinpoint Test AJ
ACCM
P0AFB:1C
Hybrid/EV Battery System Voltage High: Circuit Voltage Out of Range
GO to Pinpoint Test AJ
ACCM
U0001:88
High Speed CAN Communication Bus: Bus Off
GO to Pinpoint Test AP
ACCM
U0100:00
Lost Communication with ECM/PCM "A": No Sub Type Information
GO to Pinpoint Test AL
ACCM
U0111:00
Lost Communication With Battery Energy Control Module "A": No Sub Type Information
GO to Pinpoint Test AM
ACCM
U0140:00
Lost Communication With Body Control Module: No Sub Type Information
GO to Pinpoint Test P
ACCM
U3000:04
Control Module: System Internal Failure
GO to Pinpoint Test AS
ACCM
U3000:42
Control Module: General Memory Failure
GO to Pinpoint Test AS
ACCM
U3000:49
Control Module: Internal Electronic Failure
GO to Pinpoint Test AS
BCMC
B3A01:00
A/C Refrigerant Distribution Valve Actuator "C" Control Circuit/Open: No Sub Type Information
GO to Pinpoint Test AV
BCMC
B3A02:00
A/C Refrigerant Distribution Valve Actuator "C" Control Circuit Low: No Sub Type Information
GO to Pinpoint Test AV
BCMC
B3A03:00
A/C Refrigerant Distribution Valve Actuator "C" Control Circuit High: No Sub Type Information
GO to Pinpoint Test AV
BCMC
P2611:00
A/C Refrigerant Distribution Valve "A" Control Circuit/Open: No Sub Type Information
GO to Pinpoint Test AT
BCMC
P2612:00
A/C Refrigerant Distribution Valve "A" Control Circuit Low: No Sub Type Information
GO to Pinpoint Test AT
BCMC
P2613:00
A/C Refrigerant Distribution Valve "A" Control Circuit High: No Sub Type Information
GO to Pinpoint Test AT
BCMC
P2CFC:00
A/C Clutch Control Circuit: No Sub Type Information
GO to Pinpoint Test B
BCMC
P2CFD:00
A/C Clutch Control Circuit Low: No Sub Type Information
GO to Pinpoint Test B
BCMC
P2CFE:00
A/C Clutch Control Circuit: No Sub Type Information
GO to Pinpoint Test B
BCMC
P2E62:00
Engine Coolant Bypass Valve "E" Control Circuit/Open: No Sub Type Information
GO to Pinpoint Test AU
BCMC
P2E63:00
Engine Coolant Bypass Valve "E" Control Circuit Low: No Sub Type Information
GO to Pinpoint Test AU
BCMC
P2E64:00
Engine Coolant Bypass Valve "E" Control Circuit High: No Sub Type Information
GO to Pinpoint Test AU
HVAC
B102E:11
Air Quality Sensor: Circuit Short To Ground
GO to Pinpoint Test Y
HVAC
B102E:15
Air Quality Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test Y
HVAC
B102E:92
Air Quality Sensor: Performance or Incorrect Operation
GO to Pinpoint Test Y
HVAC
B1081:07
Left Temperature Damper Motor: Mechanical Failure
GO to Pinpoint Test G
HVAC
B1081:11
Left Temperature Damper Motor: Circuit Short To Ground
GO to Pinpoint Test G
HVAC
B1081:12
Left Temperature Damper Motor: Circuit Short To Battery
GO to Pinpoint Test G
HVAC
B1081:13
Left Temperature Damper Motor: Circuit Open
GO to Pinpoint Test G
HVAC
B1082:07
Right Temperature Damper Motor: Mechanical Failure
GO to Pinpoint Test H
HVAC
B1082:11
Right Temperature Damper Motor: Circuit Short To Ground
GO to Pinpoint Test H
HVAC
B1082:12
Right Temperature Damper Motor: Circuit Short To Battery
GO to Pinpoint Test H
HVAC
B1082:13
Right Temperature Damper Motor: Circuit Open
GO to Pinpoint Test H
HVAC
B1083:07
Recirculation Damper Motor: Mechanical Failure
GO to Pinpoint Test I
HVAC
B1083:11
Recirculation Damper Motor: Circuit Short To Ground
GO to Pinpoint Test I
HVAC
B1083:12
Recirculation Damper Motor: Circuit Short To Battery
GO to Pinpoint Test I
HVAC
B1083:13
Recirculation Damper Motor: Circuit Open
GO to Pinpoint Test I
HVAC
B1086:07
Air Distribution Damper Motor: Mechanical Failure
GO to Pinpoint Test J
HVAC
B1086:11
Air Distribution Damper Motor: Circuit Short To Ground
GO to Pinpoint Test J
HVAC
B1086:12
Air Distribution Damper Motor: Circuit Short To Battery
GO to Pinpoint Test J
HVAC
B1086:13
Air Distribution Damper Motor: Circuit Open
GO to Pinpoint Test J
HVAC
B10AF:11
Blower Fan Relay: Circuit Short To Ground
GO to Pinpoint Test N
HVAC
B10AF:15
Blower Fan Relay: Circuit Short To Battery or Open
GO to Pinpoint Test N
HVAC
B10AF:15
Blower Fan Relay: Circuit Short To Battery or Open
GO to Pinpoint Test O
HVAC
B10B3:11
Right Panel Air Discharge Temperature: Circuit Short To Ground
GO to Pinpoint Test AA
HVAC
B10B3:15
Right Panel Air Discharge Temperature: Circuit Short To Battery or Open
GO to Pinpoint Test AA
HVAC
B10B4:11
Right Floor Air Discharge Temperature: Circuit Short To Ground
GO to Pinpoint Test AA
HVAC
B10B4:15
Right Floor Air Discharge Temperature: Circuit Short To Battery or Open
GO to Pinpoint Test AA
HVAC
B10B5:11
Left Panel Air Discharge Temperature: Circuit Short To Ground
GO to Pinpoint Test AA
HVAC
B10B5:15
Left Panel Air Discharge Temperature: Circuit Short To Battery or Open
GO to Pinpoint Test AA
HVAC
B10B6:11
Left Floor Air Discharge Temperature: Circuit Short To Ground
GO to Pinpoint Test AA
HVAC
B10B6:15
Left Floor Air Discharge Temperature: Circuit Short To Battery or Open
GO to Pinpoint Test AA
HVAC
B10B7:11
Rear Air Discharge Temperature: Circuit Short To Ground
GO to Pinpoint Test AG
HVAC
B10B7:15
Rear Air Discharge Temperature: Circuit Short To Battery Or Open
GO to Pinpoint Test AG
HVAC
B10B9:12
Blower Control: Circuit Short To Battery
GO to Pinpoint Test N
HVAC
B10B9:14
Blower Control: Circuit Short To Ground or Open
GO to Pinpoint Test N
HVAC
B10BA:12
Rear Blower Control: Circuit Short To Battery
GO to Pinpoint Test AX
HVAC
B10BA:14
Rear Blower Control: Circuit Short To Ground or Open
GO to Pinpoint Test AX
HVAC
B11E3:07
Rear HVAC Damper Motor: Mechanical Failure
GO to Pinpoint Test AG
HVAC
B11E3:11
Rear HVAC Damper Motor: Circuit Short To Ground
GO to Pinpoint Test AG
HVAC
B11E3:12
Rear HVAC Damper Motor: Circuit Short To Battery
GO to Pinpoint Test AG
HVAC
B11E3:13
Rear HVAC Damper Motor: Circuit Open
GO to Pinpoint Test AG
HVAC
B11E4:07
Rear Air Distribution Damper Motor: Mechanical Failure
GO to Pinpoint Test AF
HVAC
B11E4:11
Rear Air Distribution Damper Motor: Circuit Short to Ground
GO to Pinpoint Test AF
HVAC
B11E4:12
Rear Air Distribution Damper Motor: Circuit Short To Battery
GO to Pinpoint Test AF
HVAC
B11E4:13
Rear Air Distribution Damper Motor: Circuit Open
GO to Pinpoint Test AF
HVAC
B11E5:11
Left HVAC Damper Position Sensor: Circuit Short To Ground
GO to Pinpoint Test G
HVAC
B11E5:15
Left HVAC Damper Position Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test G
HVAC
B11E6:11
Right HVAC Damper Position Sensor: Circuit Short To Ground
GO to Pinpoint Test H
HVAC
B11E6:15
Right HVAC Damper Position Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test H
HVAC
B11E7:11
Air Distribution Damper Position Sensor: Circuit Short To Ground
GO to Pinpoint Test J
HVAC
B11E7:15
Air Distribution Damper Position Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test J
HVAC
B11EC:12
Rear HVAC Blower Control Input: Circuit Short To Battery
GO to Pinpoint Test AD
HVAC
B11EC:14
Rear HVAC Blower Control Input: Circuit Short To Ground or Open
GO to Pinpoint Test AD
HVAC
B11F0:11
Air Intake Damper Position Sensor: Circuit Short To Ground
GO to Pinpoint Test I
HVAC
B11F0:15
Air Intake Damper Position Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test I
HVAC
B1364:07
Left Rear Temperature Damper Motor: Mechanical Failure
GO to Pinpoint Test AH
HVAC
B1364:11
Left Rear Temperature Damper Motor: Circuit Short To Ground
GO to Pinpoint Test AH
HVAC
B1364:12
Left Rear Temperature Damper Motor: Circuit Short To Battery
GO to Pinpoint Test AH
HVAC
B1364:13
Left Rear Temperature Damper Motor: Circuit Open
GO to Pinpoint Test AH
HVAC
B1379:11
Rear Cabin Temperature Sensor: Circuit Short To Ground
GO to Pinpoint Test BB
HVAC
B1379:15
Rear Cabin Temperature Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test BB
HVAC
B14D3:11
Left Rear Panel Discharge Sensor: Circuit Short To Ground
GO to Pinpoint Test BA
HVAC
B14D3:15
Left Rear Panel Discharge Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test BA
HVAC
B14D4:11
Left Rear Floor Discharge Sensor: Circuit Short To Ground
GO to Pinpoint Test BA
HVAC
B14D4:15
Left Rear Floor Discharge Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test BA
HVAC
B1580:11
Console Airflow Shut Off Door Position Sensor: Circuit Short To Ground
GO to Pinpoint Test AZ
HVAC
B1580:15
Console Airflow Shut Off Door Position Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test AZ
HVAC
B1581:07
Console Airflow Shut Off Door Damper Motor: Mechanical Failure
GO to Pinpoint Test AZ
HVAC
B1581:11
Console Airflow Shut Off Door Damper Motor: Circuit Short To Ground
GO to Pinpoint Test AZ
HVAC
B1581:12
Console Airflow Shut Off Door Damper Motor: Circuit Short To Battery
GO to Pinpoint Test AZ
HVAC
B1581:13
Console Airflow Shut Off Door Damper Motor: Circuit Open
GO to Pinpoint Test AZ
HVAC
B1582:11
Left Panel Discharge Sensor #3: Circuit Short To Ground
GO to Pinpoint Test BA
HVAC
B1582:15
Left Panel Discharge Sensor #3: Circuit Short To Battery or Open
GO to Pinpoint Test BA
HVAC
B158C:11
Air Distribution Damper Position Sensor #3: Circuit Short To Ground
GO to Pinpoint Test AF
HVAC
B158C:15
Air Distribution Damper Position Sensor #3: Circuit Short To Battery or Open
GO to Pinpoint Test AF
HVAC
B158F:11
Left HVAC Damper Position Sensor #3: Circuit Short To Ground
GO to Pinpoint Test AH
HVAC
B158F:15
Left HVAC Damper Position Sensor #3: Circuit Short To Battery or Open
GO to Pinpoint Test AH
HVAC
B159B:11
Cabin Temperature Sensor #3: Circuit Short To Ground
GO to Pinpoint Test BB
HVAC
B159B:15
Cabin Temperature Sensor #3: Circuit Short To Battery or Open
GO to Pinpoint Test BB
HVAC
B159E:07
Air Distribution Damper Motor #3: Mechanical Failure
GO to Pinpoint Test AF
HVAC
B159E:11
Air Distribution Damper Motor #3: Circuit Short To Ground
GO to Pinpoint Test AF
HVAC
B159E:12
Air Distribution Damper Motor #3: Circuit Short To Battery
GO to Pinpoint Test AF
HVAC
B159E:13
Air Distribution Damper Motor #3: Circuit Open
GO to Pinpoint Test AF
HVAC
B1A61:11
Cabin Temperature Sensor: Circuit Short To Ground
GO to Pinpoint Test E
HVAC
B1A61:15
Cabin Temperature Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test E
HVAC
B1A63:11
Right Solar Sensor: No Sub Type Information
GO to Pinpoint Test Z
HVAC
B1A63:15
Right Solar Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test Z
HVAC
B1A64:11
Left Solar Sensor: No Sub Type Information
GO to Pinpoint Test Z
HVAC
B1A64:15
Left Solar Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test Z
HVAC
B1A69:11
Humidity Sensor: Circuit Short To Ground
GO to Pinpoint Test E
HVAC
B1A69:15
Humidity Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test E
HVAC
B1B71:11
Evaporator Temperature Sensor: Circuit Short To Ground
GO to Pinpoint Test F
HVAC
B1B71:15
Evaporator Temperature Sensor: Circuit Short To Battery or Open
GO to Pinpoint Test F
HVAC
B1B7D:11
Rear Air Distribution Actuator: Circuit Short to Ground
GO to Pinpoint Test AF
HVAC
B1B7D:15
Rear Air Distribution Actuator: Circuit Short To Battery or Open
GO to Pinpoint Test AF
HVAC
C1B14:11
Sensor Supply Voltage A: Circuit Short to Ground
GO to Pinpoint Test AC
HVAC
C1B14:12
Sensor Supply Voltage A: Circuit Short to Battery
GO to Pinpoint Test AC
HVAC
P24AE:09
Particulate Matter Sensor Circuit: Component Failure
GO to Pinpoint Test AW
HVAC
P24AE:8F
Particulate Matter Sensor Circuit: Erratic
GO to Pinpoint Test AW
HVAC
P24AE:92
Particulate Matter Sensor Circuit: Performance or Incorrect Operation
GO to Pinpoint Test AW
HVAC
U0140:00
Lost Communication With Body Control Module: No Sub Type Information
GO to Pinpoint Test P
HVAC
U0155:00
Lost Communication With Instrument Panel Cluster (IPC) Control Module: No Sub-Type Information
GO to Pinpoint Test Q
HVAC
U0165:00
Lost Communication With HVAC Control Module - Rear: No Sub Type Information
GO to Pinpoint Test S
HVAC
U0249:00
Lost Communication With Entertainment Control Module -Rear "B": No Sub Type Information
GO to Pinpoint Test T
HVAC
U0253:00
Lost Communication With Accessory Protocol Interface Module: No Sub Type Information
GO to Pinpoint Test V
HVAC
U025D:00
Lost Communication With Front Controls Interface Module "B": No Sub Type Information
GO to Pinpoint Test W
HVAC
U0401:00
Invalid Data Received from ECM/PCM A: No Sub-Type Information
GO to Pinpoint Test AQ
HVAC
U0401:82
Invalid Data Received from ECM/PCM A: Alive / Sequence Counter Incorrect / Not Updated
GO to Pinpoint Test AQ
HVAC
U0422:68
Invalid Data Received from Body Control Module: Event Information
GO to Pinpoint Test AQ
HVAC
U0422:81
Invalid Data Received from Body Control Module: Invalid Serial Data Received
GO to Pinpoint Test AQ
HVAC
U0452:00
Invalid Data Received From Restraints Control Module: No Sub Type Information
GO to Pinpoint Test AQ
HVAC
U054A:68
Invalid Data Received From Entertainment Control Module-Rear "B": Event Information
GO to Pinpoint Test AQ
HVAC
U055E:68
Invalid Data Received From Front Controls Interface Module "B": Event Information
GO to Pinpoint Test AQ
HVAC
U1000:00
Solid State Driver Protection Active -Driver Disabled: No Sub Type Information
GO to Pinpoint Test X
HVAC
U2024:51
Control Module Cal-Config Data: Not Programmed
GO to Pinpoint Test AR
HVAC
U2100:00
Initial Configuration Not Complete: No Sub Type Information
GO to Pinpoint Test AR
HVAC
U3000:49
Control Module: Internal Electronic Failure
GO to Pinpoint Test AS
HVAC
U3003:16
Battery Voltage: Circuit Voltage Below Threshold
GO to Pinpoint Test AN
HVAC
U3003:17
Battery Voltage: Circuit Voltage Above Threshold
GO to Pinpoint Test AO
PCM
P0532:00
A/C Refrigerant Pressure Sensor A Circuit Low: No Sub Type Information
GO to Pinpoint Test A
PCM
P0533:00
A/C Refrigerant Pressure Sensor A Circuit High: No Sub Type Information
GO to Pinpoint Test A
PCM
P0645:00
A/C Clutch Relay Control Circuit: No Sub Type Information
GO to Pinpoint Test B
PCM
P06A0:00
Variable Compressor Control Circuit: No Sub Type Information
GO to Pinpoint Test C
PCM
P1464:00
A/C Demand Out Of Self Test Range: No Sub Type Information
GO to Pinpoint Test M
PCM
P193E:00
A/C Clutch Request Signal: No Sub Type Information
GO to Pinpoint Test AB
PCM
P2183:00
Engine Coolant Temperature Sensor 2: Circuit Range/Performance
GO to Pinpoint Test BC
PCM
P2184:00
Engine Coolant Temperature Sensor 2: Circuit Low
GO to Pinpoint Test BC
PCM
P2185:00
Engine Coolant Temperature Sensor 2: Circuit High
GO to Pinpoint Test BC
PCM
P2186:00
Engine Coolant Temperature Sensor 2: Circuit Intermittent/Erratic
GO to Pinpoint Test BC
PCM
P2600:00
Coolant Pump "A" Control Circuit/Open: No Sub Type Information
GO to Pinpoint Test D
PCM
P2601:00
Coolant Pump "A" Control Circuit Performance/Stuck Off: No Sub Type Information
GO to Pinpoint Test D
PCM
P2602:00
Coolant Pump "A" Control Circuit Low: No Sub Type Information
GO to Pinpoint Test D
PCM
P2603:00
Coolant Pump "A" Control Circuit High: No Sub Type Information
GO to Pinpoint Test D
PCM
P26BE:00
Engine Coolant Bypass Valve "D" Control Circuit Low: No Sub Type Information
GO to Pinpoint Test BH
PCM
P26BF:00
Engine Coolant Bypass Valve "D" Control Circuit High: No Sub Type Information
GO to Pinpoint Test BH
RHVAC
B10B8:63
Push Buttons: Circuit / Component Protection Time-Out
GO to Pinpoint Test AI
RHVAC
U0140:00
Lost Communication With Body Control Module: No Sub Type Information
GO to Pinpoint Test P
RHVAC
U0164:00
Lost Communication With HVAC Control Module: No Sub Type Information
GO to Pinpoint Test R
RHVAC
U0247:00
Lost Communication With Seat Control Module "F": No Sub Type Information
GO to Pinpoint Test U
RHVAC
U0422:68
Invalid Data Received From Body Control Module: Event Information
GO to Pinpoint Test AQ
RHVAC
U3000:41
Control Module: General Checksum Failure
GO to Pinpoint Test AS
RHVAC
U3000:42
Control Module: General Memory Failure
GO to Pinpoint Test AS
RHVAC
U3003:16
Battery Voltage: Circuit Voltage Below Threshold
GO to Pinpoint Test AN
RHVAC
U3003:17
Battery Voltage: Circuit Voltage Above Threshold
GO to Pinpoint Test AO
SOBDMC
P01EB:96
Engine Coolant Heater "A" Control Circuit Performance: Component Internal Failure
GO to Pinpoint Test AK
SOBDMC
P0531:00
A/C Refrigerant Pressure Sensor "A" Circuit Range/Performance: No Sub Type Information
GO to Pinpoint Test A
SOBDMC
P0534:00
A/C Refrigerant Charge Loss: No Sub Type Information
GO to Pinpoint Test A
SOBDMC
P0D6D:00
A/C Compressor Motor Voltage "A" Low: No Sub Type Information
GO to Pinpoint Test AJ
SOBDMC
P0D6F:00
A/C Compressor Motor Current High: No Sub Type Information
GO to Pinpoint Test AJ
SOBDMC
P0D71:00
A/C Compressor Control Module Internal Temperature Sensor Performance: No Sub Type Information
GO to Pinpoint Test AJ
SOBDMC
P2611:00
A/C Refrigerant Distribution Valve "A" Control Circuit/Open: No Sub Type Information
GO to Pinpoint Test AT
SOBDMC
P2612:00
A/C Refrigerant Distribution Valve "A" Control Circuit Low: No Sub Type Information
GO to Pinpoint Test AT
SOBDMC
P2613:00
A/C Refrigerant Distribution Valve "A" Control Circuit High: No Sub Type Information
GO to Pinpoint Test AT
SOBDMC
P26FD:00
A/C Compressor Internal Control Module Performance: No Sub Type Information
GO to Pinpoint Test AJ
SOBDMC
P2D41:00
A/C Compressor Motor Voltage "B" Performance: No Sub Type Information
GO to Pinpoint Test AJ
SOBDMC
P2D42:00
A/C Compressor Motor Voltage "B" Low: No Sub Type Information
GO to Pinpoint Test AJ
SOBDMC
P2D44:00
A/C Compressor Motor Performance: No Sub Type Information
GO to Pinpoint Test AJ
SOBDMC
P2DA4:00
Coolant Heater "A" Internal Control Module Performance: No Sub Type Information
GO to Pinpoint Test AK
SOBDMC
P2DA5:00
Coolant Heater "A" Supply Voltage Circuit: No Sub Type Information
GO to Pinpoint Test AK
SOBDMC
P2DA6:00
Coolant Heater "A" Over Temperature: No Sub Type Information
GO to Pinpoint Test AK
SOBDMC
P2DA7:00
Coolant Heater "A" Internal Control Module Control Module System Voltage: No Sub Type Information
GO to Pinpoint Test AK
SOBDMC
P2E62:00
Engine Coolant Bypass Valve "E" Control Circuit/Open: No Sub Type Information
GO to Pinpoint Test AU
SOBDMC
P2E63:00
Engine Coolant Bypass Valve "E" Control Circuit Low: No Sub Type Information
GO to Pinpoint Test AU
SOBDMC
P2E64:00
Engine Coolant Bypass Valve "E" Control Circuit High: No Sub Type Information
GO to Pinpoint Test AU
SOBDMC
U069E:81
Lost Communication With Coolant Heater "A": Invalid Serial Data Received
GO to Pinpoint Test AK
SOBDMC
U069E:87
Lost Communication With Coolant Heater "A": Missing Messages
GO to Pinpoint Test AK
Global Customer Symptom Code (GCSC) Chart
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices...
Repair
NOTE:
This procedure may be carried out on rubber hoses only. If a
plastic washer hose is damaged, a new washer hose must be installed.
Locate and verify the damaged washer hose.
Cut the hose cleanly and remove the damaged portion of the washer hose...